Ajax TOCCO Toccotron AC Especificações Página 31

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 30
OM-229 158 Page 27
Press the Run button to resume program operation and the yellow indicator LED will illuminate.
Press the Stop button to end the program.
SECTION 7 MAINTENANCE
7-1. Routine Maintenance
! Disconnect power
before maintaining.
Maintain more often
during severe conditions.
= Check = Change = Clean = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
3
Months
Section 4-8
Damaged or Unreadable
Labels
Output Bus Bar Con-
tacts
Ground Sense Lead Re-
ceptacles
Operator Interface Over-
lay
Cracked Cables
Every
6
Months
Section 9-8
Inside Unit
Vista de página 30